Product_Header_1920x384_ArmaSound

ArmaSound Barrier E

High performance noise barrier for ArmaSound Industrial Systems

Technical information ArmaSound Barrier E
Product_pdpimage_800x800_ArmaSound_Barrier_E_WATERMARK

Material type

  • Vinyl sound barrier mat. Thermoplastic polymer com

Special features

  • Does not contain lead, unrefined aromatic oils and bitumen.
PropertyValue / AssessmentStandard / Test method
Temperature range
Service temperature
Min. °CMin. °FMax. °CMax. °F
-20-465149
Fire performance
Practical fire behaviourSelf-extinguishing, burn rate (flame progression) < 100 mm/min.FMVSS 302
Physical attributes
Mass per unit area2mm: 4.8 to 5.50 kg/m² (0,98 to 1.13 lb/ft²)
3mm: 7.2 to 8.25 kg/m² (1.47 to 1.69 lb/ft²)
4mm: 9.7 to 11.0 kg/m² (1.99 to 2.25 lb/ft²)
Mechanical properties
Tensile strength≥ 1.8 MPa (≥ 261 psi)ISO 371
Elongation≥ 25%ISO 371
Acoustic performance
Sound transmission class, STC22mm (5 kg/m²): 28
3mm (7.5 kg/m²): 30 dB.
4mm (10 kg/m²): 31
ASTM E 4133
System acoustic insertion lossWhen used as part of a system ArmaSound Barrier E complies to ISO 15665 Class C and Shell DEP 31.46.00.31 - Gen Class D.ISO 3741, ASTM E1222, ISO 15665
Other technical features
Adhesion and fixingAdhesive 520 or Adhesive HT625 shall be used for reliable adhesion. 19mm wide stainless steel bands with wing clips (or blind rivets) shall be used for fixing and final securing. 50 mm long x 0.5 mm thick x 19 mm wide - stainless steel "S" clips are also required on vertical piping and vessels.
Application conditions4,5Application temperature: +5 to +35°C (+41 to 95°F)
Max. relative humidity: 80%
Shelf life6Max. 3 years
StorageMaterial shall be stored indoors, in clean and dry conditions, away from direct sunlight.

1Type 1 dumb-bell test piece. Maximum specimen thickness according to the test standard is 3mm.

2Nominal values.

3Based on single test results. Can be used for information / reference only.

4Application temperature refers to the ambient temperature during installation and the surface temperature of the substrate (e.g. ArmaClad Arma-Chek R covering) to which the product is installed.

5For environmental conditions outside the given range, please contact Technical Services.

6Shelf life (maximum storage time) is limited to ensure that only currently manufactured products are installed on projects. This limitation is restricted solely to storage of the product and does not affect the lifetime of product after it has been installed.