Arma-Chek D
The durable pre-covered ArmaFlex system to withstand mechanical stress
Technical information Arma-Chek D
Property | Value / Assessment | Standard / Test method | ||||||
---|---|---|---|---|---|---|---|---|
Temperature range | ||||||||
Service temperature1,2 |
| EN 14304, EN 14706, EN 14707 | ||||||
Thermal conductivity | ||||||||
Remarks | Depends on ArmaFlex substrate. | EN ISO 13787, EN 12667, EN ISO 8497 | ||||||
Fire Performance and Approvals | ||||||||
Reaction to fire | Arma-Chek D (AF) E | EN 13823, EN ISO 11925-2 | ||||||
Resistance to water vapour | ||||||||
Water vapour diffusion resistance factor | Sheets and tubes μ ≥ 15.000 | EN 13469, EN 12086 | ||||||
Physical attributes | ||||||||
Density | 1200 kg/m³ (covering) | |||||||
Dimensions and tolerances | In acc. with EN 14304, Table 1 (ArmaFlex substrate) | EN 822, EN 823, EN 13467 | ||||||
Mechanical properties | ||||||||
Resistance to mechanical impact | Good | |||||||
Weather and UV resistance | ||||||||
UV resistance3 | Excellent | EN ISO 4892-2 | ||||||
Health and environment | ||||||||
Health aspects | Dust- and fibre-free. | |||||||
Other technical features | ||||||||
Shelf life | Tape, sheets, tubes, self-adhesive: 1 year | |||||||
Storage | To be stored in dry, clean rooms at normal relative humidity (50% to 70%) and ambient temp. (0°C–35°C). | |||||||
1When there are fluctuations in temperature, the surface may wrinkle slightly, as elastomeric products expand and contract in these circumstances. However, these superficial changes do not have any impact on the performance of the material. The wrinkles usually disappear as soon as the plant is heated to its original operating temperature. 2For temperatures below -50 °C please contact our Customer Service Center to request for the corresponding technical information. 3In outdoor applications the colour may fade. This does not have any impact on the functionality of the covering or the insulation material. |