ArmaFlex Rail SD
First FEF insulation that meets HL2 according EN45545-2
Technical information ArmaFlex Rail SD
Property | Value / Assessment | Standard / Test method | ||||||
---|---|---|---|---|---|---|---|---|
Temperature range | ||||||||
Service temperature |
| EN 14304, EN 14706, EN 14707 | ||||||
Thermal conductivity | ||||||||
Declared thermal conductivity |
| EN 12667, EN ISO 8497, EN ISO 13787 | ||||||
Transportation | ||||||||
Reaction to fire - hazard level | Tape and sheets 3 mm: HL3,R1
Sheets and tubes 9-25 mm: HL2,R1 | EN 45545-2 | ||||||
Burning behaviour of materials for use in motor vehicles | Burning behaviour for the use in motor vehicles (ECE Regulations)
Passed Annex 6,7,8,9 | ECE R-118 | ||||||
NFPA 130 American fire test to railway components | 3-13 mm ls≤ 25 Ds(4,0) ≤100 | ASTM E162, ASTM E662 | ||||||
Fire performance | ||||||||
Practical fire behaviour | Self-extinguishing, does not drip, does not spread flames | |||||||
Resistance to water vapour | ||||||||
Water vapour diffusion resistance factor | μ ≥ 5.000 | EN 13469, EN 12086 | ||||||
Physical attributes | ||||||||
Dimensions and tolerances | In accordance with EN 14304, table 1; | EN 13467, EN 822, EN 823 | ||||||
Weather and UV resistance | ||||||||
UV resistance | Protection against UV-radiation is necessary, see TB 142 | |||||||
Health and environment | ||||||||
Fungal growth | No fungal growth according to tests | ASTM G21 | ||||||
Additional features | SCCP, MCCP-free | |||||||
Other technical features | ||||||||
Shelf life | Self-adhesive tapes, self-adhesive sheets: 1 year | |||||||
Storage | Can be stored in dry, clean rooms at normal relative humidity (50% to 70%) and ambient temperature (0 °C – 35 °C). | |||||||
1+85 °C, for products with a self-adhesive layer. |